Renuvion® RF-Helium Plasma for Subdermal Skin Tightening, Facial Contouring and Skin Rejuvenation of the Face and Neck

ITEM TYPE:

Journal Article

AUTHORS:

Richard D. Gentile, MD, MBA

ABSTRACT:

An abstract was not written for this paper.

APYX® MEDICAL DISCLOSURES:

FINANCIAL & CONTENT DISCLOSURE
The authors declared no potential conflicts of interest with respect to the research, authorship, and publication of this article. No funding was received for this article. Drs DiBernardo, Bharti, and Kortesis are paid consultants for Apyx Medical, and Dr Duncan is a member of Apyx Medical’s Medical Advisory Board. The opinions contained herein are those of the authors and do not necessarily represent the official position or policies of Apyx Medical, Inc.

MANUFACTURING DISCLOSURE
Apyx Medical manufactures and owns the Renuvion®/J-Plasma® technology discussed in this article.

INDICATIONS FOR USE & INTENDED USE DISCLOSURES

    • The Renuvion APR Handpiece is intended for the delivery of radiofrequency energy and/or helium plasma for cutting, coagulation, and ablation of soft tissue during open surgical procedures.
    • The Renuvion APR Handpiece is indicated for use in subcutaneous dermatological and aesthetic procedures to improve the appearance of lax (loose) skin in the neck and submental region.
    • The Renuvion APR Handpiece is intended to be used with compatible electrosurgical generators owned by Apyx Medical (specifically BVX-200H, BVX-200P, APYX-200H, APYX-200P, APYX-RS3, and APYX-JS3).
    • Renuvion Dermal Handpiece is indicated for dermatological procedures for the treatment of moderate to severe wrinkles and rhytides, limited to patients with Fitzpatrick skin types I, II, or III.
    • Apyx Medical wants to present to you with current scientific discourse. Specific usage outside of the cleared indications may not be safe or effective.
    • The use of Renuvion with liposuction has not been approved or cleared by the FDA.

RISKS

    • As with all energy devices there are inherent risks associated with its use. Risk associated with the use of the Renuvion APR may include: helium embolism into the surgical site due to inadvertent introduction into the venous or arterial blood supply system, unintended burns (deep or superficial), pneumothorax, temporary or permanent nerve injury, ischemia, fibrosis, infection, pain, discomfort, gas buildup resulting in temporary and transient crepitus or pain, bleeding, hematoma, seroma, subcutaneous induration, pigmentation changes, increased healing time, scarring, asymmetry and/or unacceptable cosmetic result.
    • Risks associated with the use of the Renuvion Dermal System include but are not limited to hypertrophic scarring, milia/acne, telangiectasia (spider veins), skin discoloration/ hypopigmentation, dormant infection reactivation, infection, bruising or bleeding. Warning: Application of more than one treatment pass in the perioral area, on the forehead, and along the jawline has been associated with hypertrophic scarring.

As with any procedure, individual results may vary. As with all energy devices there are inherent risks associated with its use, refer to the IFU for further information.