Enhanced Lipocontouring of the Arms

ITEM TYPE:

Journal Article

AUTHORS:

Julie Khanna and Maryam Saheb-Al-Zamani

ABSTRACT:

The visibility of arm contour in both men and women has been a source of discussion throughout time. Arm strength and athleticism is not limited to the male physique only. Iconic women such as Madonna and Michelle Obama have made discussions about arm contour more and more commonplace. Over the years arm contour has been a difficult area to address due to the thinness of the skin which often required surgical excision and unsightly scars. Liposuction of the arm has advanced to not only allow for improved contour but also options of refining muscular definition. With the addition of energy-based technologies such as radiofrequency, we can offer less invasive options to patients who may have previously only been candidates for excisional procedures. Liposuction of the arms can be performed under local anesthesia. This chapter introduces a new algorithm for assessment and treatment of arm contour which incorporates newer energy-based devices along with surgical options.

APYX® MEDICAL DISCLOSURES:

FINANCIAL & CONTENT DISCLOSURE
The authors declared no potential conflicts of interest with respect to the research, authorship, and publication of this article. No funding was received for this article. Drs DiBernardo, Bharti, and Kortesis are paid consultants for Apyx Medical, and Dr Duncan is a member of Apyx Medical’s Medical Advisory Board. The opinions contained herein are those of the authors and do not necessarily represent the official position or policies of Apyx Medical, Inc.

MANUFACTURING DISCLOSURE
Apyx Medical manufactures and owns the Renuvion®/J-Plasma® technology discussed in this article.

INDICATIONS FOR USE & INTENDED USE DISCLOSURES

    • The Renuvion APR Handpiece is intended for the delivery of radiofrequency energy and/or helium plasma for cutting, coagulation, and ablation of soft tissue during open surgical procedures.
    • The Renuvion APR Handpiece is indicated for use in subcutaneous dermatological and aesthetic procedures to improve the appearance of lax (loose) skin in the neck and submental region.
    • The Renuvion APR Handpiece is intended to be used with compatible electrosurgical generators owned by Apyx Medical (specifically BVX-200H, BVX-200P, APYX-200H, APYX-200P, APYX-RS3, and APYX-JS3).
    • Apyx Medical wants to present you with current scientific discourse. Specific usage outside of the cleared indications may not be safe or effective.
    • The use of Renuvion with liposuction has not been approved or cleared by the FDA.

RISKS

    • As with all energy devices there are inherent risks associated with its use. Risk associated with the use of the Renuvion APR may include: helium embolism into the surgical site due to inadvertent introduction into the venous or arterial blood supply system, unintended burns (deep or superficial), pneumothorax, temporary or permanent nerve injury, ischemia, fibrosis, infection, pain, discomfort, gas buildup resulting in temporary and transient crepitus or pain, bleeding, hematoma, seroma, subcutaneous induration, pigmentation changes, increased healing time, scarring, asymmetry and/or unacceptable cosmetic result.

As with any procedure, individual results may vary. As with all energy devices there are inherent risks associated with its use, refer to the IFU for further information.